Manifold Mixing Unit, also called underfloor heating manifold pump mixing valve unit, is a key equipment used in floor heating system. It integrates multiple functions such as water flow distribution, mixing and pumping to ensure the efficient operation of floor heating system.
The manifold mixing unit is an innovative fluid management device that integrates efficient water flow distribution, precise mixing control, stable pumping and delivery, and intelligent automatic exhaust functions. It is designed for the efficient integrated operation of complex fluid systems. The combination of its modular structure and intelligent control technology can significantly optimize the process flow and reduce energy consumption.
Multi-channel intelligent distribution: The adjustable diversion structure realizes balanced distribution of multi-branch water flow, supports dynamic pressure compensation, ensures the consistency of flow in each circuit, and adapts to the needs of complex pipe network systems.
Remote control: Thermostatic head of the mixing valve with a remote sensor. The adjustable range is 20°C to 70°C
Fully automatic exhaust technology: With an intelligent exhaust(air vent) valve, it monitors and discharges the accumulated gas in the pipeline in real time, completely eliminates the risk of gas blockage, noise and cavitation, and ensures continuous and stable operation of the system.
This mixing control unit is essential for adjusting water temperature and optimizing flow conversion systems. Widely used in mixed heating systems on both ground and radiator heating, it provides independent control to regulate radiator heating, increasing water flow and pressure. This versatile unit ensures that the ground heating meets temperature requirements, prolongs the life of the pipeline system, and promotes international green energy consumption reduction.

| Test precedure | |||
|---|---|---|---|
| Primary circuit maximum temperature: | 90℃ | Climatic regulation: | 11.5kW |
| Maximum pressure: | 10bar | Mixing valve pressure drop (thermostatit regulation): |
Kv3 |
| Primary circuit max △P: | 1bar | Pressure drops with open bypass valve (thermostatic regulation): |
Kvmax4.8 |
| Secondary control range: (thermostatic regulation) |
20℃-70℃ | Thermometer scale: | 0℃-80℃ |
| Heating capacity that can be exchanged at AT7℃, △Pavailable 0.25 bar: |
Mixing unit inlet connections: | 1″”BSP male | |
| Thermostatic regulation: | 10kW by-pass pos.0 | Mixing unit inlet connections: | DN24x19tpi |
| Thermostatic regulation: | 12.5kW by-pass pos.5 | Lowara Ecocirc circulator connections: | 1″1/2BSP male union |
| Mixing valve unit flow meter | ||
|---|---|---|
| Primary circuit maximum temperature: | 90℃ | Climatic regulation: |
| Scale display | Flow rate of mixed water(L/m) | Flow rate of the hot water(L/m) |
| 0 | 24.7 | 31.3 |
| 1 | 23.1 | 32 |
| 2 | 22.1 | 32.7 |
| 3 | 21.5 | 32.7 |
| 4 | 21.5 | 33.1 |
| 5 | 21.3 | 33.9 |